Stainless steel, Plasma / air shield 260 a cutting, Marking – Hypertherm HPR260 Manual Gas Preventive Maintenance Program Rev.5 User Manual

Page 286: English, Metric

Advertising
background image

APPENDIX C – CUT CHARTS FOR PREVIOUS SYSTEM REVISIONS

HPR260 Auto Gas

Instruction Manual

c-17

Stainless steel

N

2

Plasma / Air Shield

260 A Cutting

Flow rates – lpm/scfh

N

2

Air

Preflow

127 / 270

0 / 0

Cutflow

54 / 114

116 / 245

Plasma Shield Plasma Shield Plasma Shield

mm

Volts

mm

factor %

seconds

6

160

10

157

12

161

0.4

15

163

0.5

20

164

0.6

25

168

0.8

32

171

1.0

38

179

44

190

50

195

Plasma Shield Plasma Shield Plasma Shield

in

Volts

in

factor %

seconds

1/4

160

3/8

157

1/2

161

0.4

5/8

163

0.5

3/4

164

0.6

1

168

0.8

1-1/4

171

1.0

1-1/2

179

1-3/4

190

2

200

Marking

Amperage

Amps

mm

in

mm/min ipm

N

2

N

2

10

10

10

10

18

2.5

0.100

6350

250

Marking

Speed

Select

Gases

Set

Preflow

Set

Cutflow

Torch-to-Work

Distance

Volts

120

20

N/A

14

6

240

0.300

200

0.3

140

110

95

70

50

35

Pierce Delay

Time

in

ipm

N

2

Air

12

60

79

69

0.150

Arc

Voltage

Torch-to-Work

Distance

Cutting

Speed

Initial Pierce

Height

Select

Gases

Set

Preflow

Set

Cutflow

Material

Thickness

English

79

69

3.8

515

N

2

Air

875

6375

N/A

365

180

2960

2520

1590

1300

12

60

Initial Pierce

Height

Pierce Delay

Time

mm

mm/m

7.5

200

0.3

3440

Metric

Select

Gases

Set

Preflow

Set

Cutflow

Material

Thickness

Arc

Voltage

Torch-to-Work

Distance

Cutting

Speed

Arc

Voltage

220407

220398

220307

220344

220405

220406

Advertising