NGSME16T2H User Manual | 215

Security/Switch>snmp commu add abc

Security/Switch>snmp commu add test 192.168.2.100
255.255.255.0

SNMP Trap Server

Setting

Enter the SNMP Trap Configuration Group

Security/Switch/SNMP>trap

Type 'up' to move up one level or '/' to go to root level

Security/Switch/SNMP/Trap>

Syntax:

Security Switch SNMP Trap Mode [enable|disable]

Security Switch SNMP Trap Version [1|2c|3]

Security Switch SNMP Trap Community [<community>]

Security Switch SNMP Trap Destination [<ip_addr_string>]

Security Switch SNMP Trap IPv6 Destination [<ipv6_addr>]

Example:

Security/Switch/SNMP/Trap>mode ena

Security/Switch/SNMP/Trap>version 2c

Security/Switch/SNMP/Trap>community public

Security/Switch/SNMP/Trap>destination 192.168.2.100

Result:

Trap Mode : Enabled

Trap Version : 2c

Trap Community : public

Trap Destination : 192.168.2.100

Trap IPv6 Destination : ::