6.6 217IF Communications Protocols
6-27
6
6.6.3
OMRON Communications
OMRON Communications Specifications
The following table shows the general specifications for OMRON communications, and
which of these specifications are supported by the 217IF Module.
Table 6.12 OMRON Communications Specifications
General OMRON Specifications
OMRON Specifications
Supported by the 217IF
Transmission
Method
RS-232C
RS-232C
Synchronization
Start-stop synchronization
Start-stop synchronization
Transmission
Speed
300/600/1200/2400/4800/9600 bps
1200/2400/4800/9600/19200 bps
Data Format
Data: 7-bit ASCII
8-bit JIS
Parity: Odd, even, none
Stop bits: 1 or 2 bits
Data: 7-bit ASCII
8-bit JIS
Parity: Odd, even, none
Stop bits: 1 or 2 bits
Error Detection
Frame check sequence (FCS)
Frame check sequence (FCS)
RTS/CTS Control Yes/No
Yes
Communications
Protocol
Host Link
Supported
Uploading or downloading of user
memory
Not supported
No protocol (ASCII I/O mode)
No protocol