2 setting switches, Dip switch (sw1) – Yaskawa MP920 Communications Module User Manual
Page 153
Advertising
7.2 Part Names
7-7
7
7.2.2
Setting Switches
DIP Switch (SW1)
The DIP Switch is used for the self-diagnosis.
The pins are all set to OFF (right) prior to shipment.
* The default values are shown below.
IP address: 192.168.1.1
Engineering port No.: 10000 (UDP)
The 218IFA Module can perform only engineering communications with
the MPE720 at initial start-up.
Indicator
Name
Name
Status
Function
−
Not used.
−
Not used.
INIT
Initial start-up
ON
Starts up with the default IP address and the
engineering port number.
*
OFF
Starts up with the IP address set at MPE720
and the engineering port number.
TEST
Test
ON
Self-diagnosis (Performs self-diagnosis
when started at status ON.)
SW1
INIT
TEST
OFF
ON