8 Example Communications Module Applications

8.3.2 Cable Specifications

8-18

CN1 Cables

Note: Mitsubishi Electric Controller model: A1SJ71C24

CN3 Cables

* For the AJ71UC24, switch SW24, which is used to connect the terminat-

ing resistance, must be set to ON (MELSEC).

Note: 1. Mitsubishi Electric Controller models:

A1SJ71C24
AJ71UC24
A171QC24
A1SJ71UC24-R4: R2 cannot be connected.
(This is because the RS-232C 1: 1 connection address is fixed at
“0”.)

2. Connect the cable so that the terminating resistance for the 217IF

Module is connected.

Refer to 8.1.2 Cable Specifications for the MPE720 Programming Device connections.

217IF

MELSEC Controller

D-sub 9-pin

D-sub 9-pin

Signal Name

Pin No.

Pin No.

Signal Name

FG

1

1

CD

TXD

2

2

RD

RXD

3

3

SD

RTS

4

4

DTR

CTS

5

5

SG

DSR

6

6

DSR

SG

7

7

RS

DTR

9

8

CS

217IF

Screw Terminal Block *

MR 8-pin

Signal Name

Signal Name

Pin No.

Left

Right

RXR

4

SD A

RX (-)

1

SG

RX (+)

2

SD B

TXR

5

FG

TX (-)

6

RD A

TX (+)

7

N.C.

SG

8

RD B

SH

3

Shield

FG

To SG on
the right

Shield

INFO