3 Communications Protocols

3.3.2 Slave Function

3-16

„

MSG-RCV Program

In the top half, the Slave function (MSG-RCV) parameters are set in the first scan after star-
tup.
In the lower half, messages are transmitted. At this time, the Communications Module type
and the protocol type are set in the device type (DEV-TYP) and protocol type (PRO-TYP),
respectively, as the Master function inputs.
With the protocol type, the setting value of the Extended MEMOBUS, MEMOBUS,
MELSEC, and OMRON protocols is 1. This value is specified in the transmission parameter
setting of each Communications Module. See the section on the transmission definitions for
each Communications Module.

SB000004

DB000210

DB000211

DB000212

Command

Executing

Normal completion

Abnormal completion

MSG-RCV

EXECUTE BUSY

ABORT COMPLETE

DEV-TYP ERROR
PRO-TYP
CIR-NO
CH-NO

SEND PARAM
DA00000

00006

00001

00001

00001

SB000004

Interrupt

MEMOBUS communications
Line No.1
Channel No.1

The normal completion or abnor-
mal completion coil turns ON at
reception completion.

Sends a Receive Message
command from connection
ST#1.

The executing coil turns ON when
the CPU receives the command.

Normal completion

Normal counter

Abnormal completion

DB000211

DB000212

IFON

IEND

DEND

INC DW00024

Error counter

INC

DW00025

Ended by a transmission error

Error pulse counter added

Turns ON command message has
been received normally and re-
sponse message has been trans-
mitted normally.
Normal pulse counter added

At power ON, set the param-
eters in the first scan.

SB000003

One scan at power ON

IFON

Coil offset setting

00000

00000

00000

00000

00000

DW00008

DW00009

DW00010

DW00011

DW00012

DW00013

DW00024

DW00025

Relay offset setting

Input offset setting

Holding register offset setting

Write range lower bytes

Write range higher bytes

Normal pulse counter clear

Error counter clear

DW00000

DW00026

DW00027

Processing result stored

Status stored

DW00001

DW00002

DW00028

DW00029

Remote ST# stored

FC stored

DW00004

DW00005

DW00030

DW00031

Data address stored

Data size stored

DW00006

DW00007

DW00032

Remote CP# stored

00000

IEND

32767

00000

DW00014

System clear

00000

FOR i=0 TO 31 BY 1

FEND

0

DW0000i

DW register clear

DEV-TYP

PRO-TYP

L scan: SB03
H scan: SB01

215IF=1
217IF=5
218IF=6

Set the device

type.

= 1

Protocol type.

Extended MEMOBUS
(MEMOBUS alias)
MEMOBUS
MELSEC
OMRON
No protocol = 2
(Word specification)
No protocol = 3
(Byte specification)