7.8 Connections with MELSEC

7-41

7

07H

Sets the bit devices to be monitored in 16-point units

120 words

(326 points)

No

−

Sets the word devices to be monitored in 1-point units

20 points

No

−

08H

Monitors devices for which monitor data registration has
been performed (in bit units)

−

No

−

09H

Monitors devices for which monitor data registration has
been performed (in word units)

−

No

−

17H

Reads extension file registers in 1-point units

256 points

No

−

18H

Writes extension file registers in 1-point units

256 points

No

−

19H

Randomly specifies block numbers and device numbers, and
writes to the extension file registers in 1-point units

40 points

No

−

1AH

Registers the extension file registers to be monitored in 1-
point units

20 points

No

−

1BH

Monitors extension file registers for which monitor data reg-
istration has been performed

−

No

−

3BH

Reads extension file registers by directly specifying them in
1-point units

256 points

No

−

3CH

Writes extension file registers by directly specifying them in
1-point units

256 points

No

−

0EH

Reads the contents of the buffer memory of the special func-
tion unit

256 bytes

(128 words)

No

−

0FH

Writes data to the buffer memory of the special function unit

256 bytes

(128 words)

No

−

0AH

Reads the main sequence program

256 steps

No

−

0BH

Reads the sub-sequence program

256 steps

No

−

0CH

Writes the main sequence program

256 steps

No

−

0DH

Writes the sub-sequence program

256 steps

No

−

1EH

Reads the main microcomputer program

256 bytes

No

−

1FH

Reads the sub-microcomputer program

256 bytes

No

−

20H

Writes the main microcomputer program

256 bytes

No

−

21H

Writes the sub-microcomputer program

256 bytes

No

−

1CH

Reads the comment data

256 bytes

No

−

1DH

Writes the comment data

256 bytes

No

−

39H

Reads extended comment data

256 bytes

No

−

3AH

Writes extended comment data

256 bytes

No

−

10H

Reads the parameter contents

256 bytes

No

−

11H

Writes the parameter contents

256 bytes

No

−

12H

Recognizes and checks the rewritten parameter contents

−

No

−

13H

Requests for remote RUN/STOP

−

No

−

14H

15H

Reads the PC model name

−

No

−

16H

Loopback test

256 bytes

Yes

08H

60H

Fixed buffer communications

507 words

Yes

31H

Table 7.8 Common MELSEC ACPU Commands (cont’d)

Command

Description

Qty

218IFA

Support

*

MEMOBUS

Command