5 215IF Module

5.6.3 Example of a Network Configuration Using the Relay Function

5-32

„

215IF Network Configuration 2

In the following example, three 215IF Modules are mounted to one MP920 Controller.

Settings

1. NW#1 ST#1

• Message Relay Function: Yes
• No. of Relayed Network 1: 1 to 1
• No. of Relayed Network 2: Not set

2. NW#2 ST#10

• Message Relay Function: Yes
• No. of Relayed Network 1: 2 to 1
• No. of Relayed Network 2: 4 to 4

3. NW#3 ST#20

• Message Relay Function: Yes
• No. of Relayed Network 1: 3 to 3
• No. of Relayed Network 2: Not set

RS-232C

ST#11

ST#12

NW#2

ST#31

ST#32

NW#4

ST#2

ST#3

NW#1

ST#21

ST#22

CP-215

NW#3

CP-215

CP-215

ST#1

ST#10

ST#20

MPE720

ST#30

MP920