Setting default values – Yaskawa MP920 Communications Module User Manual
Page 166

7 218IF Module
7.5.5 Transmission Parameter Settings
7-20
Setting Default Values
The transmission parameters can be set to their default values without entering each parame-
ter, by clicking Edit (E) and then Transmission Parameters Default Settings (D) on the
CP-218 Transmission Definitions menu. The following table shows the default values for
each transmission parameter.
This operation does not return the remote stations’ Ethernet addresses or the connection parameters to
their default settings.
Table 7.5 Default Values for Transmission Parameters
Transmission Parameter
Default Value
IP Address
192.168.001.001
Response Time
0
Count of Retry
0
Subnet Mask
000.000.000.000
Gateway IP Address
000.000.000.000
System Port No. (DIAG. Port No./Engineering
Port)
10,000
TCP Zero Window Timer Value
3
TCP Retry Time
500
TCP Close Time
60
IP Assemble Time
30
MAX. Packet Length
1,500
INFO