D.1 In-panel Wiring

D-7

D

„

CP-215 Repeater-TT Cable Connections

The following figure shows a 215IF transmission line connection example.

Fig. D.4 CP-215 Repeater-TT Transmission Line Connection Example

• Connect pins 8 and 1 of the CN1 and CN3 transmission connectors (MR-8LM(G)) on the

Repeater to SRD+ and SRD-, respectively.

• If the Repeater is located at the end of the transmission line, short-circuit pins 4 and 5 of

the CN1 or CN3 to connect the internal 75

Ω terminating resistance.

75

Ω

75

Ω

1
4
5

8

SRD-

SRD+

CN1
MR-8LM(G)

CN3
MR-8LM(G)

CP-215 Repeater-TT

215IF in-panel cable

Terminator

SRD-

SRD+