Yaskawa AC Drive Z1000 AC Drive HVAC Fan User Manual

Page 177

Advertising
background image

Protective tube

2.

Insert the connector for fan B2 and guide the lead wire for fan B2 so the cable hook holds it in place.
Insert the connector for fan B1.

Connector for fan B1

Fan B1

Fan B2

Connector for fan B2

Figure 2.19 Cooling Fan Wiring: 5A0125 and 5A0145

3.

Make sure that the protective tube does not stick out beyond the fan guard.

n

Cooling Fan Wiring: 5A0192 and 5A0242

1.

Position the protective tube so the fan connector sits in the center of the protective tube.

Protective tube

2.

In the space between fans 1 and 2, place the fan connector for fan B2 in front of the fan connector for fan B1.

3.

Place the connector for fan B3 between fans B2 and B3.

Cable cover

Fan B3

Fan B2

Connector for fan B3

Connector for fan B1

Connector for fan B2

Fan B1

Figure 2.20 Cooling Fan Wiring: 5A0192 and 5A0242

4.

Double-check the relay connector to ensure it is properly connected.

5.

Reattach the cable cover to its original position and tighten the screws so the fan guard holds the cable cover in place.

Note:

Do not pinch the fan cable between parts when reassembling the fan unit.

2.5 Drive Cooling Fans

YASKAWA ELECTRIC SIEP YAIZ1U 03A YASKAWA AC Drive – Z1000 Programming Manual

177

2

Periodic Inspection & Maintenance

Advertising