<3> Display is in the following units: 5A0007 to 5A0017: 0.01 A units; 5A0022 to 5A0242: 0.1 A units.
<4> Set the number of motor poles to parameter E2-04, E4-04, or E5-05 depending on the motor being used.

u

Broadcast Messages

Data can be written from the master to all slave devices at the same time.
The slave address in a broadcast command message must be set to 00H. All slaves will receive the message, but will not

respond.

Register No.

Contents

0001H

Digital Input Command
bit 0

Forward Run (0: Stop 1: Run)

bit 1

Direction Command (0: Forward, 1: Reverse)

bit 2, bit 3

Reserved

bit 4

External Fault

bit 5

Fault Reset

bit 6 to B

Reserved

bit C

Multi-Function Digital Input S5

bit D

Multi-Function Digital Input S6

bit E

Multi-Function Digital Input S7

bit F

Reserved

0002H

Frequency Reference

30000/100%

u

Fault Trace Contents

The table below shows the drive fault codes that can be read out by MEMOBUS/Modbus commands from the U2-oo monitor

parameters.

Table E.3 Fault Trace / History Register Contents

Fault Code

Fault Name

0002H

Undervoltage (Uv1)

0003H

Control Power Supply Undervoltage (Uv2)

0004H

Soft Charge Circuit Fault (Uv3)

0006H

Ground Fault (GF)

0007H

Overcurrent (oC)

0008H

Overvoltage (ov)

0009H

Heatsink Overheat (oH)

000AH

Heatsink Overheat (oH1)

000BH

Motor Overload (oL1)

000CH

Drive Overload (oL2)

000DH

Overtorque Detection 1 (oL3)

0011H

External Fault at Input Terminal S3 (EF3)

0012H

External Fault at Input Terminal S4 (EF4)

0013H

External Fault at Input Terminal S5 (EF5)

0014H

External Fault at Input Terminal S6 (EF6)

0015H

External Fault at Input Terminal S7 (EF7)

001BH

Input Phase Loss (PF)

001CH

Output Phase Loss (LF)

001DH

Motor Overheat (PTC input) (oH3)

001EH

Digital Operator Connection (oPr)

001FH

EEPROM Write Error (Err)

0020H

Motor Overheat (PTC input) (oH4)

0021H

MEMOBUS/Modbus Communication Error (CE)

0022H

Option Communication Error (bUS)

Fault Code

Fault Name

0027H

Option External Fault (EF0)

0028H

PI Feedback Loss (FbL)

0029H

Undertorque Detection 1 (UL3)

002BH

High Slip Braking Overload (oL7)

0030H

Hardware Fault (including oFx)

0036H

Output Current Imbalance (LF2)

0037H

Pullout Detection (Sto)

003BH

Too Many Speed Search Restarts (SEr)

0041H

PI Feedback Loss (FbH)

0042H

External Fault 1, Input Terminal S1 (EF1)

0043H

External Fault 2, Input Terminal S2 (EF2)

0046H

Current Offset Fault (CoF)

0047H

PLC Detection Error 1 (PE1)

0048H

PLC Detection Error 2 (PE2)

004DH

Output Voltage Detection Fault (voF)

0052H

Node Setup Fault (nSE)

005AH

Motor Underload Protection (UL6)

0083H

A/D Conversion Error (CPF02)

0084H

PWM Data Fault (CPF03)

0087H

EEPROM Memory Data Error (CPF06)

0088H

Terminal Board Connection Error (CPF07)

0089H

EEPROM Serial Communication Fault (CPF08)

008CH

RAM Fault (CPF11)

008DH

Flash Memory Circuit Exception (CPF12)

E.9 MEMOBUS/Modbus Data Table