Yaskawa AC Drive Z1000 AC Drive HVAC Fan User Manual

Page 178

Advertising
background image

n

Installing the Cooling Fan Unit

1.

Reverse the procedure described above to reinstall the cooling fan unit.

Figure 2.21 Install the Cooling Fan Unit: 5A0062 to 5A0242

2.

Reattach the covers and HOA keypad.

3.

Turn on the power supply and set o4-03 to 0 to reset the Maintenance Monitor cooling fan operation time.

u

Gasket Replacement for Flange Type Enclosure (NEMA 12 Backside) Drives

n

Gasket Replacement Procedure

1.

Use a plastic scraper to remove the damaged or torn gasket without scratching the mounting surfaces.

2.

Peel off the adhesive cover from the replacement gasket.

3.

Align the holes on the mounting flange or fan bracket with the holes on the replacement gasket and apply the new

gasket.

n

Gasket Replacement Parts

Each replacement part contains two gaskets in the event that a gasket is torn during application.
Contact a Yaskawa representative or the nearest Yaskawa sales office to order replacement gaskets as required.

Table 2.6 Gasket Replacement Part Numbers

Drive Model

Replacement Part

Part Number

5A0041U

5A0052U

Mounting Flange Gasket

UGK00419-A

5A0062U

5A0077U

5A0099U

Fan Bracket Gasket

UGK00421-A

5A0125U

5A0145U

Fan Bracket Gasket

UGK00422-A

5A0192U

5A0242U

Fan Bracket Gasket

UGK00423-A

2.5 Drive Cooling Fans