Sequence Display Lab

5. Press the SCROLL key next to the flashing ENT (enter)

If the display times out before you can
press Enter, simply press the UP or
DOWN key again.

6. The top line will change to CHARGE. The millisecond time

displays the elapsed time in the current step.

7. Change the display on the controller front panel to PID-100. Use

the Scroll key to display Setpoint.

8. In Vizapp, double-click on the LSH block.

9. Change the mode to Manual and set the Result to ON.

The sequence enters the HEAT step
The controller changes to AUTO mode
with a setpoint of 90

10. Change the result back to OFF and the mode to AUTO, then

close the block.

11. Using the potentiometer, slowly raise the process temperature to

90

When the temperature reaches or exceeds
90, the sequence enters the COOK stage.

12. On the controller, switch to the sequence display

The top line shows COOK, and line 2
shows the time in step. When 20 seconds
has elapsed the sequence proceeds to the
COOL stage.

13. Switch to the PID-100 display on the controller.

The setpoint should be 20.

14. Using the potentiometer, slowly decrease the temperature to 20

The sequence enters the DRAIN step and
the controller switches to Manual mode
with a setpoint of zero.

15. In the ViZapp database, open the LSL block. Change the mode

to MANUAL and set the result to ON.

The sequence goes to the IDLE step.