1150

Brocade Network Advisor IP User Manual

53-1002947-01

Adding a policy monitor

38

Select the Check for SNMPv3 (secure SNMP) configuration check to check each target
to see if SNMPv3 is active for device data transmission and SNMPv1 and SNMPv2 are
not configured.

Select the Check for VLAN configurations match for each connection (IP only) check to
determine the consistency of VLAN configurations for each connection on the selected
IP devices.

b. Click the right arrow button to move the selected checks to the Selected Checks list.

c. Select the switches or routers to which you want to apply this policy in the Available

Switches/Routers list and click the right arrow button.

NOTE

You can use the All Fabrics targets (under the Product Groups > System Product Groups
node) in the Available Switches/Routers list) for future provisioning. Select All Fabrics and
click the right arrow button to apply this policy to all discovered fabrics.

The selected switches display in the Selected Switches/Routers list.

8. To set policy monitors for hosts, select the Host Checks tab (

Figure 453

) and complete the

following steps.

FIGURE 453

Add Policy Monitor dialog box, Hosts Checks tab

a. Select the Check for redundant connections to attached fabrics check box to determine if

there are at least the minimum number of configured physical connections between the
host and the attached fabric.

The default is 2. For more information about this check and a fix for rule violations, refer to

“Host policy monitors”

on page 1141.