5-6

Agilent E5250A User’s Guide, Edition 11

Controlling the E5250A
Switch Control Basics

Channel List and Channel Configuration

Some SCPI commands require the channel_list parameter, which determines the
relays to close/open in the E5252A or the E5255A to connect/disconnect the desired
channels. The following figure shows the basic syntax of the channel_list parameter.

Figure 5-1

Syntax of channel_list Parameter

The channel_list depends on Channel Configuration mode as described later. In the
channel_list, you can specify one or more channels.

Each specified channel consists of five digits as follows:

Card Number:

One digit decimal number: 0 to 4.

Specifies the slot number of the card that you want to control.
Depends on Channel Configuration mode. Refer to Table 5-2.

Channel Number: Four digit decimal number:

First two digits: specifies input port.

Last two digits: specifies output port.

Depends on type of card and Channel Configuration mode.
Refer to “E5252A Channel List” on page 5-15 and “E5255A
Channel List” on page 5-19
.

Channel No.
(4 digits)

Card No.
(1digit)

@

Channel No.
(4 digits)

Card No.
(1digit)

(

:

,

)

Channel No.
(4 digits)

Card No.
(1digit)

@

Channel No.
(4 digits)

Card No.
(1digit)

(

:

,

)

Advertising