Setting up the measurement environment, Setting up the measurement environment -7 – Agilent Technologies Agilent E5250A User Manual

Page 263

Advertising
background image

Agilent E5250A User’s Guide, Edition 11

9-7

Executing Sample Programs

Vth and Capacitance Measurement Program

Setting up the Measurement Environment

Before executing the program, you need to set up the measurement environment.
Table 9-3 lists the required equipment.

Connect the E5250A output to Device Under Test (DUT). For details, refer to
“Setting up Measurement Environment” on page 4-1.

And connect all equipment as shown in Figure 9-1 and Table 9-4. The E5252A must
be installed in slot1 of the E5250A.

Table 9-3

Required Equipments

Agilent Model/Part No.

Description

Qty.

E5250A

Low Leakage Switch Mainframe

1

E5252A

10

×12 Matrix Switch

1

4155/4156

Semiconductor Parameter Analyzer

1

16494A-003

Triaxial Cable (80 cm)

4

16494A-001 or -002

Triaxial Cable (1.5 m or 3 m)

6

16495F

Connector Plate

1

4284A with 4284A-006

Precision LCR Meter

1

16048D/E

Test Lead

1

1250-2405

BNC T-type Adapter

2

10833A/B/C

GPIB Cable

3