Troubleshooting - faq – ETC Cobalt Family v7.1.0 User Manual

Page 67

Advertising
background image

Cobalt 7.1 - 20140612

66

Troubleshooting - FAQ

Here are some situations that you may run into. If these don't solve the issue, contact support at

ETC

Technical Services

24/7.

Troubleshooting - Console Keys do not respond

Console is not responding to key presses

If a key gets mechanically stuck it will seem like the console is not responding - however mouse and
keyboard will still work.

• Try pressing ESC twice and test again.

Troubleshooting - Lights Are Not Responding

Lights (dimmers, devices) are connected and they are not responding.

Have you reset the console properly? See

Reset the system

.

Is the device powered properly?

Is the device set to receive the protocol you have set the board to transmit?

Is the device receiving a signal from the console?

Is the device set to the right channel address?

Is there a light source connected to the device?

Is it a lamp failure?

Is the device circuit breaker thrown?

If nothing works you may want to use a DMX tester to check that there is DMX at the receiving
devices.

Troubleshooting - Flickers

A Dimmer/device with start address below ~200 flickers or drops out at semi-
regular intervals.

• Turn off RDM at the DMX port it is plugged into using

system settings

/GCE.

If this stops flicker then device is not fully compliant with the DMX spec, inform supplier so
they can fix.