Master pages - times – ETC Cobalt Family v7.1.0 User Manual

Page 877

Advertising
background image

Cobalt 7.1 - 20140612

876

Master Pages - Times

Master Playback times can be stored in Master Pages. Times are set from 0.1seconds to 49.59 minutes
(0.1- 4959).

General Facts

• A Master Playback can have an in/wait/out time.

• A Master Page can have a general time used for all Palettes and Presets.

• A Master Page can have a BPM time for all Chases.

Master Page Times - In, Out, Wait

Fade times for a Master Playback can be stored in a Master Page.

The times are activated in the following situations

• When the master is linked from a Sequence Step.

• When you hold START and press the Master Key.

• When Flash On Time is active (SETUP & Master Key).

Function

Keys

Feedback

1. Activate the Master
Pages List

Browser >Master
Pages

The Master Pages List is
opened.

2. Activate a Master Page
List

Arrow keys

The Master Page List is
opened.

3. Go to In-Wait-Out Times Arrow keys

Each selected cell is
highlighted

4. Set a time*

[#] [MODIFY]

A time of # is set.

Master Page Times - Page Time

The Master Page Time is used for Palettes (content= palette) and Presets with In times set in %.

Function

Keys

Feedback

Set Master Page Time*

[#] [TIME] &
[PAGE]

A Master Page Time # is
set to the currently loaded
Master Page.

*The Master Page Time can be set from the Master Page List as well.

Advertising