Patch

111

• Yellow “?” means that the dimmer/ device has a warning message.Warning messages can

include:

Multiple devices’ addresses overlap

Multiple devices of different devices at this address

Patched fixture type mismatch

Patched fixture address mismatch

Offline

Detaching Devices

Pressing {Attach} twice will post the {Detach} command.

<Chan> [X] {Attach} {Attach} or <Address> [X] {Attach} {Attach} will remove the link between
that channel/address and the device at that address.

Clearing the Patch

You can clear the patch entirely by accessing the clear functions from the browser. Select {Clear}
from the main browser menu. The clear functions window will open in the CIA.

To clear the patch, click {Clear Patch}. A confirmation is required before the patch will be cleared.

To exit the clear functions screen without clearing, press the [Displays] key at any time or select a
clear button and then select {Cancel} from the confirmation screen.

Reset Patch

You can use {Reset Patch} to clear out your patch, and set it to a 1-to-1 patch.