Synchronized backup, Setting up synchronized backup – ETC Eos Titanium, Eos, and Gio v2.0.0 User Manual

Page 411

Advertising
background image

C

Multi-console and Synchronized Backup

393

Synchronized Backup

Once you have changed settings to facilitate a multi-console system on the network, you may
activate synchronized backup to ensure show data security.

Eos synchronized backup is designed so that during normal operation the primary console controls
the lighting system, and any console configured as backup or client synchronize with the primary.
The following activities will synchronize between consoles when operating in a backup system:

Playback

Record operations

Manually set data

Show file and data

Only Eos consoles, Gio consoles, Ion consoles, or RPUs can function as a primary or backup.

Setting up Synchronized Backup

Before backup is possible, you must have at least two Eos devices (Consoles or RPUs only)
connected to the network. One must be assigned as primary and one as a backup.

To assign a backup to a primary:

Step 1:

Exit the Eos environment (Browser> Exit Eos) on the console you wish to act as the

backup. This will send you to the ECU welcome screen.

Touch or click on the {Backup} button in the welcome screen. The console will then startup the Eos
software, this time in backup mode. Eos will try to connect to a master console. The CIA will say
“Waiting for Master. One moment please...”.

Step 2:

If the backup doesn’t connect after a few moments, press the {Troubleshoot}
touchbutton in the CIA. This will open the network configure screen in the CIA.

Step 3:

Select a master console from the list on the right. If no masters are available in the list,
a master console is not connected to the network.

Step 4:

Press {Change Master}. The backup Eos will synchronize with the master.

N o t e :

If this is the first time that a backup is connecting to this master, you will need to

press {Troubleshoot} and select the master.