Non-intensity parameter category timing, Manual timing at a cue level, N o t e – ETC Eos Titanium, Eos, and Gio v2.0.0 User Manual

Page 224

Advertising
background image

206

Eos Titanium, Eos, and Gio Operations Manual

Manual Timing at a Cue Level

It is possible to assign a time of “manual”, for manual parameter transition through the associated
fader.

See “Cue Playback” on page 239.

Manual times are assigned by using the {Manual} softkey

that is displayed when recording a cue.

[Record] <Cue> [4] [Time] {Manual} [Enter] - applies a manual time. If the cue had

previously been given split times, would apply a manual to the upfade, focus, color, and beam
times. If the cue had a single time, all of the timing would be “manual” and controlled by the
fader.

[Record] <Cue> [4] [Time] [Time] [Manual] [Enter] - applies a manual intensity time to the

downfade.

[Record] <Cue> [4] {Color} [Time] [Manual] [Enter] - applies a manual time to any color

data changes in cue 4.

Non-intensity Parameter Category Timing

Timing can be also applied for Focus, Color and Beam parameter categories at a cue level. By
default, FCB timing is the same as intensity upfade time. Once FCB timing is different than intensity
upfade time, those times are no longer affected by intensity upfade changes.

When you apply a time to an individual parameter category and that category has no movement,
the time is displayed in gray. The specified timing will remain in gray until that category is provided
with a move instruction, at which point it the timing will display in white.

[Record] <Cue> [2] {Color} [Time] [7] [Enter] - records cue 2 with a cue level color time of 7.

[Record] <Cue> [2] {Color} [Time] [Enter] - resets the color time of cue 2 back to the default

value.

[Record] <Cue> [2] [Time] [Time] [Time] [7] [Enter] - records cue 2 with a cue level focus

time of 7. In this example, each press of the [Time] key steps through each timing value (up
time, down time, focus time, color time and beam time.

[Record] <Cue> [2] [Time] [7] [Enter]- records cue 2 and puts a time of 7 on all parameter

categories (if F, C, B all had the same times to begin with).

N o t e :

It is not necessary to rerecord a cue to alter stored timing data. You can simply

redefine the time by specifying the cue and re-entering the time value(s).

[Cue] [5] [Time] [8] [Enter] - Redefines the all category times to 8

seconds (If FCB all had the same timing).

[Cue] [2] {Color} [Time] [5] [Enter] - Redefines color time to 5

seconds.

[Cue] [3] {Focus} [Time] [-] [2] [Enter] - Removes 2 seconds from

the current time.

[Cue] [7] {Beam} [Time] [+] [3] [Enter] - Adds 3 seconds to the

current time.

Advertising