Page 232

Advertising
background image

214

Eos Titanium, Eos, and Gio Operations Manual

Using External Links

External links can be used to trigger actions such as macros, show control, or snapshots.
Additionally, you can enter instructions that sync the “Go” of other cue lists.

When you press {Execute}, the softkeys will change to {Time Code}, {Macro}, {Relay}, {On},
{Off}, {Snapshot}, {OOS Sync}, {MIDI Raw}, and {String}.

To trigger a macro:

[Cue] [1] {Execute} [Macro] [5] [Enter] - triggers macro 5 when cue 1 is executed.

To trigger a snapshot:

[Cue] [3] {Execute} [Snapshot] [3] [Enter] - loads snapshot 3 when cue 3 is played back.

To trigger a relay either on or off:

[Cue][5] {Execute} {Relay}[1] [/] [1] {On} [Enter] - triggers relay 1/1 on (ACN Group ID /

Relay Number)

To trigger cue lists press:

• [Cue] [1] {Execute} {Cue} [4] [/] <+> [6] [/] [Enter]

• [Cue] [1] {Execute} {Cue} [2] [/] [Thru] [5] [/] [Enter]

To trigger a specific cue on another fader:

• [Cue] [4] {Execute} [Cue] [4] [/] [5] [Enter]

When cue list triggers are set, the system will automatically execute same numbered cues on the
associated cue list. For example, assume that the last instruction above was applied to cue list 1,
cue 1. When cue 1/1 is executed, any cues numbered “1” in cue list 2 thru 5 will be executed
accordingly. If there is not a cue 1 in those lists, no action is taken on them. If there are cue numbers
on secondary cue lists that are not in cue list 1, those cues are skipped and the subsequent cue
taken as an “out-of-sequence” cue when triggered.

When cues are taken on the primary list out of sequence, only like-numbered cues on the
secondary lists will be replayed. For example, if you go to cue 12 on the primary list, and there is a
cue 12 on the secondary list, cue 12 on all lists is executed. However, if cue 12 does not exist in the
secondary list, that list will be unaffected by the go to cue command. Out of sequence sync can be
enabled to make sure secondary lists assume the same position in the show as they would on
linear playback.

{OOS Sync} can be used to change that behavior per cue list. {OOS Sync} is disabled by default.
When enabled, OOS Sync will display in the cue list index's external links column. {OOS Sync}
should be enabled in the secondary lists, not on the list that contains the execute command.

When OOS Sync is enabled, any out of sequence cue fired from a cue list that is synced with
another cue list will trigger the closest earliest cue that exists if the correct cue does not.

For Example:

Cue list 1 is synced with cue list 2. Cue 1/3 is fired. Since cue 2/3 does not exist, cue 2/2

will fire instead. If OOS Sync was disabled, a cue in cue list 2 would only fire if it has the

same cue number as cue list 1.

Removing a trigger:

To remove a trigger, access the cue number and press {Execute}, the record target type and press
[Enter].

• [Cue] [5] {Execute} {Cue/Macro/Snapshot} [Enter]

Advertising