Local i/o (eos ti and gio only), Local dmx outputs, The following settings are available – ETC Eos Titanium, Eos, and Gio v2.0.0 User Manual

Page 400: Show control gateway

Advertising
background image

382

Eos Titanium, Eos, and Gio Operations Manual

Local I/O (Eos Ti and Gio Only)

This screen allows you to configure the ports on the back of the Eos Ti and Gio desks.

Local DMX Outputs

The following settings are available:

Enable - enables DMX output from the local ports on an Eos Ti and Gio.

Default Output Protocol - enables DMX as a default output.

Ports - the settings for the two DMX ports.

Address - sets the starting address for the port.

Doubled - enables dimmer doubling on the port.

Speed - sets the speed for the ports. Options are: maximum, fast, medium, and slow.

The speed may need to be adjusted for certain devices. The default speed is maximum.

Dimmer Doubled Offset - this offset matches the default offset in CEM+ / CEM3 when

configuring your Sensor dimmer rack for dimmer doubling. The default offset is 20,000.

Show Control Gateway

Group IDs

Allows you to set the group number for the MIDI In and MIDI Out ports. Group numbers can be from
1-32. Default for both ports is 1.

Contact Closure (remote trigger connector)

Allows you to set the Group and Address In values for the remote trigger input on the back of Eos
Ti and Gio.

N o t e :

To input RS-232 into a desk, you will need to use a Net3 I/O Gateway.