8

Basic Manual Control

151

Multiple Intensity Channels

When a fixture with multiple intensity parameters is patched, Eos assigns it a master intensity. The
master intensity can be used to control the multiple intensities together. The master intensity is
handled in the same way as the intensity of a single intensity channel. Levels can be set via the
level wheel, from the keypad, and the encoders. The other intensities will default to 100%.

Control of the individual intensities of a multiple intensity channel is handled using the parameter
buttons in the CIA (see

Manual Control of Non-intensity Parameters (NPs), page 141

) or the

encoders (see

Custom Control, page 146

). Levels assigned to the individual intensities will act

independent of each other and the master intensity.

[1][0][0] {Intens 3} [At] [5][0] - sets intensity 3 of channel 100 to 50% intensity.

[1][0][0] [At] [7][5] - sets the master intensity of channel 100 to 75% intensity. All

intensities for channel 100 will be mastered to 75% unless they have a separate

intensity set.

In Table view, Eos will default to showing all intensity parameters associated with the channels.

In summary view, the master intensity is shown. If one of the
multiple intensities has a value, an ‘+’ will display beside the
master intensity.