N o t e – ETC Eos Titanium, Eos, and Gio v2.0.0 User Manual

Page 321

Advertising
background image

23

Using About

303

{Dimmer Feedback} - appears when the current address is patched to a dimmer in an ETC Sensor
rack with a CEM+ or CEM3. Sensor feedback must be enabled. See

Sensor Feedback, page 373

and

Errors and Warnings, page 110

for more information.

{Dimmer Feedback} displays the following information:

Name (dimmer name)

Module type

Rack/Position

Rack dimmer level (displayed as a percentage)

Rack dimmer source

Recorded load

Actual load

{Dimmer Feedback} displays the following information, which can be modified from Eos by clicking
on the value and entering in a new value:

Firing Mode

Control Mode

Curve

Threshold

Scale Minimum

Scale Maximum

Preheat Enable

Preheat Timing

Advanced Features (AF) Enable

Eos support the following softkey commands from this display:

{Ignore Errors}

{Clear Errors}

N o t e :

For Sensor feedback, the CEM+ must be running software version 3.0 or later.

N o t e :

Clearing CEM+ or CEM3 errors from Eos will be temporary unless the errors have

been fixed at the CEM+ or CEM3. Errors displayed on Eos will clear on their own

once they have been cleared from the CEM+ or CEM3. Some CEM+ or CEM3

errors can only be cleared at the CEM+ or CEM3.

Advertising