Eos Configuration Utility

373

ArtNet

This sets the subnet for ArtNet data from this desk. The valid ArtNet Start range for this setting is 0-
15.

Broadcast Type

Directed Broadcast - Broadcast packets are directed to a subnet based on the IP address

and subnet mask of the sender.

Limited Broadcast - The limited broadcast address is 255.255.255.255. It is limited because

routers will never forward datagrams with that destination address. This means that
datagrams with the limited broadcast address are confined to the particular network segment
on which they originate.

Output to Visualizer from Offline

Checking this box allows for output in offline mode for use with a visualization program.

Backup Takes Over At Higher Priority

This enables the backup device in a multi-console system to take over at one priority higher than
the master if the master goes offline.

Backup Automatically Takes Control

Switches to the backup automatically if the primary should go offline.

Allowed Output Addresses

A range or ranges of addresses that can be assigned to limit the number of output addresses. The
default setting is to allow addresses 1 through 65536.

Interface Protocols

MultiConsole

Clicking in the enable box will allow for multiconsole communication on the selected port.

See

“Multi-console and Synchronized Backup” on page 389.

Network Type
This setting adjusts the timeout period before a backup device will take control from the master.

Standard - After five seconds of no response from the master, the backup will assume the

master has disconnected and will then take control.

Engineered - After 1.6 seconds of no response from the master, the backup will assume the

master has disconnected and will then take control.

Sensor Feedback

Clicking in the enable box will allow Eos to receive feedback over the network from a Sensor
rack.This option is “Enabled” by default. See

About Address, page 302

for more information.

RDM

Clicking in the enable box will allow Eos to perform RDM functionality including device discovery.
See

{Patch} Display and Settings, page 100

and

About Address, page 302

.

.

N o t e :

RDM requires use of a Net3 Gateway using version 5.1 or higher.