Rockwell Automation 1441-PEN25-Z Enpac 2500 Data Collector User Manual

Page 142

Advertising
background image

142

Rockwell Automation Publication GMSI10-UM002D-EN-E - August 2012

Chapter 4

Collecting and Reviewing Data

Velocity

Performs a standard acceleration to velocity vibration measurement.
These are the settings for the measurement parameters.

Table 36 - Types of Offroute Measurements

Type

Description

Parameter

Value

Display Format

Spectrum

Units

A -> V

High-pass frequency

1.1 Hz

Input Channel

X

Fmax 1

kHz

Lines/Samples

400 Lines

Averages

4

Overlap

50%

Type

Spectral

Ext. Trigger Slope

Positive

Trigger Level

2 V

Bin Zeroing

On

Advertising
This manual is related to the following products: