Recording the measurement, Saving a time recorder setup and measurement – Rockwell Automation 1441-PEN25-Z Enpac 2500 Data Collector User Manual

Page 244

Advertising
background image

244

Rockwell Automation Publication GMSI10-UM002D-EN-E - August 2012

Chapter 9

Time Recorder Application

Recording the Measurement

Once you have previewed the measurement and you are satisfied with the
parameter settings, you can record the measurement. To initiate data recording,
press F4 (Rec.) on the Preview screen.

During data recording, the live time waveform freezes on the screen, and the
(recording) time remaining counts down in the message area. If any errors occur
during the recording, an error message is displayed in the message area.

Refer to Recorder Status Indicators on page 242

.

If you need to pause the recording, press F4 (Pause) on the Recorder - Taking
Data screen. While paused, the Enpac 2500 reverts back to Preview mode
showing the live time waveform. The Pause function becomes the Resume
function. To resume data recording press F4 (Resume). Note that the recorded
time signal is not continuous while the recording is paused.

When the recording ends, the Recorder - Save Data screen automatically appears,
allowing you to save the recording to a file.

Refer to Saving a Time Recorder Setup and Measurement on page 244

.

Saving a Time Recorder Setup and Measurement

The time recorder setup parameters and recorded time waveforms can be saved to
a file which can then be recalled at a later time. The recorded time waveforms are
stored in a .wav file format, and the last block of the recorded .wav file is saved in a
comma separated value (.csv) file format.

Channel You are

Currently Viewing

Overall Reading

Message Area

Cursor Time

Cursor Amplitude

Recording Time

Remaining

Advertising
This manual is related to the following products: