Chapter 4

Collecting and Reviewing Data

Use the descriptions in this table to help you configure the parameters in the
Offroute User screen.

Table 37 - Offroute User Parameters

Parameter Name

Description

Values/Comments

Change Name

Changes the name of the user-defined measurement point.
Select the hierarchy level for which you want to change the name. A window
opens at the bottom of the screen. Use the numeric key pad to enter a new name
and press F2 (OK).

Select Level (default)
Default Locn
Default Point
1 Horiz
Default

Collection

The type of data to collect with this measurement.

Overall/Signature (default): collect both a magnitude reading and
a signature.
Overall only: collect a magnitude reading only.
Signature only: collect a signature only.
RSS Overall: collect a digital overall measurement.

Display Format

The display format of the measurement.

Spectrum (default)
Time
Phase
Order

Units

The measurement units for the transducer.
The [S] designation refers to a static measurement that you must manually enter
with the numeric key pad. All dynamic measurements and temperature process
points require a transducer to make the measurement.

Accel (G) (default)
gSE
RPM
A->V (mm/s)
Vel (IPS)
Vel (mm/s)
A->D (mil)
A->D (μm)
V->D (mil)
V-D> (μm)
Disp (mil)
Disp (μm)
Volts
EUs [S]
Temperature [S]
Current (A) [S]
Pressure (PSI) [S]
Flow (m

3

/s) [S]

Rot. Speed [S]
Linear Displ (mm)
Count [S}
Count Rate [S]
Volts [S]
Accel (G) [S]
Vel. (IPS) [S]
Vel (mm/s) [S]
Disp (mil) [S]
Disp (μm) [S]

Coupling

The type of coupling that will be applied to the measurement.

AC: couples the input voltage signal.
DC: couples the input voltage signal.
ICP: (default) selects a standard ICP accelerometer requiring a
current source power supply