Multi-channel Measurements Chapter 6

4.

Set Collection to the collection specification that you created for the cross
channel phase. Select a band Filter, for example, 1st Order.

5.

In the Location pane, select the new location that you just created. Choose
Edit > Copy to copy the location.

6.

Move to an empty row in the Location pane and choose Edit > Paste to
paste the new location into the spreadsheet.

7.

Edit the new location. Make sure you set Lo. Channel to 2.

8.

Include these locations in a list. You can create a new list or recall the
current list. The locations must be tagged to create a group list.

9.

Add the two locations to a group list by double-clicking the Group column
in the Location pane.

The current group number appears in the Group column. Make sure you
assign the locations the same group number. The group is then loaded with
the list to the Enpac 2500.

This figure shows a typical setup for a cross channel phase measurement.

Figure 33 - Cross Channel Phase Measurement Definitions

10.

Connect the data collector to the computer and load the list to the Enpac
2500.

See

Loading Lists to the Data Collector on page 106

for details.

11.

Once you have prepared the Enpac 2500 data collector for data collection,
select the route and collect the cross channel phase measurement.

See

Collect a Cross Channel Phase Measurement on page 178

.