282

Rockwell Automation Publication GMSI10-UM002D-EN-E - August 2012

Chapter 10

Run Up/Coast Down Application

Reviewing Run Up/Coast
Down Measurements

You can review previously saved Run Up/Coast Down measurements with the
Enpac 2500. The Enpac saves the recorded data in the form of a time waveform
(.wav file).

1.

Select RUCD on the Main Menu and press the READ/OK key.

The RUCD screen appears.

2.

Select Review Data and press the READ/OK key.

The RUCD - Review Data screen appears.

3.

Highlight the filename that you want review and press F4 (Open).

If you select a .wav file, the RUCD - WAV Setup screen appears (see
below). Otherwise the appropriate plot setup screen appears. Refer to the
appropriate section in the chapter for details.