227

Balancing Application

Chapter 8

Adding the Trial Weight and Taking a Measurement in Plane 2

The Add Trial Weight - Plane 2 screen appears upon completion of the plane 1
trial run measurement.

To Manually Enter the Trial Weight

Use the UP and DOWN ARROW keys to highlight the parameters. Press the
RIGHT ARROW key and then enter the trial weight, angle, or radius value
using the numeric key pad. When entry is complete, press the LEFT ARROW
key.

1.

In the Mass option, enter the trial weight.

This is the amount of weight you will attach to the rotor in the second
plane.

2.

In the Angle option, enter the angle (in degrees) at which you are about to
attach to the rotor in the second plane.

The angle is measured from the reference mark in the direction specified in
the Movement option on the Balance Setup screen.

Refer to Balance Setup Parameters on page 211

.

3.

In the Radius option, enter the radius of the trial weight.

To Estimate the Trial Weight

1.

Press F3 (Estimate).

2.

Enter the mass of the rotor using the key pad and press F2 (OK).

Advertising
This manual is related to the following products: