Collect orbit measurements – Rockwell Automation 1441-PEN25-Z Enpac 2500 Data Collector User Manual

Page 168

Advertising
background image

168

Rockwell Automation Publication GMSI10-UM002D-EN-E - August 2012

Chapter 6

Multi-channel Measurements

Collect Orbit Measurements

Once you have selected the route and have finished setting up the orbit Offroute
parameters, you can begin collecting the data.

Follow these steps to collect data.

1.

Attach the transducer to the correct location.

2.

Press Enter to start ranging your measurement for the current point.

The Enpac 2500 ranges and collects the data.

The measurement screen appears.

IMPORTANT

If Trigger (Offroute Orbit parameter) is set to Off, the Specify rpm dialog box
appears when collecting an Offroute orbit measurement.

You must specify the rpm:

Press F2 (dBase) to use the rpm downloaded with the route.
Press F3 (Type In) to manually enter the rpm value
Press F4 (Spec) to take the rpm from a spectrum.
If you press F4 (Spec), a spectrum appears on the screen. Position the cursor
on the peak that represents the machine running speed and press F2 (OK).

The rpm value that is specified is used to set the Fmax appropriately and the
order filtering frequency.

The bDase function
appears only if a rpm value
is downloaded with the
route.