Displaying measurements in table format, Setting up the table, Refer to displaying measurements in – Rockwell Automation 1441-PEN25-Z Enpac 2500 Data Collector User Manual

Page 268

Advertising
background image

268

Rockwell Automation Publication GMSI10-UM002D-EN-E - August 2012

Chapter 10

Run Up/Coast Down Application

Displaying Measurements in
Table Format

The magnitude and phase of selected orders at the varied RPM speeds are
displayed in a table.

Setting Up the Table

1.

Select Table on the RUCD - Display Select screen and press F4 (Display).
The RUCD - Table Setup screen appears.

2.

Highlight the option and press the RIGHT ARROW key to open a menu
of choices.

3.

Select the choice by pressing the arrow keys or type in a value using the
numeric keypad.

4.

Press the LEFT ARROW key to save your selection.

Use the descriptions in

Table 48

to help you configure the parameters.

5.

When you are finished, press F4 (Display) to display the table.

Refer to Displaying the Table on page 270

.

To highlight an option, use the UP and
DOWN ARROW keys.

Table 48 - Table Parameters

Parameter Name

Description

Values/Comments

Start Spd (RPM)

Sets the start speed of the recorded data for the table.

10…3600 RPM
This defaults to the Start Spd value set in the RUCD
Setup screen.

See Table 44 on page 258

.

Stop Spd (RPM)

Sets the stop speed of the recorded data for the table.

10…3600 RPM
This defaults to the Stop Spd value set in the RUCD
Setup screen.

See Table 44 on page 258

.