220

Rockwell Automation Publication GMSI10-UM002D-EN-E - August 2012

Chapter 8

Balancing Application

The Enpac 2500 automatically measures the speed, vibration, and phase.
The values are constantly updated on the screen.

4.

When the speed, vibration, and phase values are stable, press READ/OK.
The residual measurement is complete.

The following message appears.

5.

Do one of the following.

Press F3 (No) if you do not want to trim the residual. The Vibration
Summary Table appears.

Refer to Reviewing Data on page 233

.

Press F2 (Yes) to trim the residual. The Enpac 2500 calculates the trim
correction weights and displays the following screen. Note that you can
split the trim weight and modify the radius.

Refer toTo Split the Correction Weight on page 219

for details.

TIP

The green status indicator illuminates when the measurement is
complete.

Refer to Status Indicators on page 25

.