Rockwell Automation 1441-PEN25-Z Enpac 2500 Data Collector User Manual

Page 143

Advertising
background image

Rockwell Automation Publication GMSI10-UM002D-EN-E - August 2012

143

Collecting and Reviewing Data

Chapter 4

Accel Time

Performs a standard vibration Acceleration measurement and collects waveform data.
These are the settings for the measurement parameters.

High Res.

The measurement configuration is based upon the most recently selected measurement in the
Route Manager
The setup is identical to the active measurement in the active Route, except the Lines/Samples
setting is doubled (increased by a factor of 2) to a maximum of
25,600 lines (up to 12,800 for two-channel measurements and up to 6,400 for three
and four-channel measurements).
For example, if the active Route Points Lines/Samples setting is 400 Lines, the High Resolution
Offroute measurements Lines/Samples setting is 800 Lines.
This lets you take a high resolution look at your active Route measurement. Measurement
parameters are set to:
Overlap – 50%
Bin Zeroing – On

Table 36 - Types of Offroute Measurements

Type

Description

Parameter

Value

Display Format

Time

Units

Accel (G)

High-pass frequency

1.1 Hz

Input Channel

X

Fmax

8

kHz

Lines/Samples

256…32768 samples

Averages

4 (time sync)
If a trigger is defined for the active Route point, if
no trigger is detected only 1 average is taken.

Overlap

50%

Type

Time

Ext. Trigger Slope

Positive

Trigger Level

2 V

Bin Zeroing

On

Advertising
This manual is related to the following products: