Specifications

Signal Measurement cont.

Input Signal Range

Transducer Check

Signal

Auto Range

Dynamic Range

Accuracy

Frequency Range

Filters - High Pass

Bearing Condition

gSE Filters

ESP Filters

Real Time Rate

FFT Resolution

Time Block Length

Averaging

Alarms

Note Codes

Window Types

Non ICP: ±12 V or 0 to 24 V
ICP: 0 to +20 V

Bias Voltage Integrity

RMS
Peak
Peak to Peak
True Peak
True Peak to Peak

Yes

90 dB typical

5%

Upper (Fmax) all inputs = 40 kHz
Lower (Fmin) DC input = DC
AC/ICP input = 0.16 Hz
H/W integrated input = 0.22 Hz

H/W filters are 2nd order
3 dB points 0.22, 0.44, 2, 5.3, 10, 23.1, 70 Hz
2, 10, 70 filter supported in route mode

gSE
ESP

100, 200, 500, 1000, 2000, 5000 Hz

0.6-1.25; 1.25-2.5; 2.5-5; 5-10; 10-20 kHz

40 kHz (single channel)

100…12,800 lines

256…16,384 samples

Time
Spectral
Exponential
Peak Hold

Overall
Spectrum

100 note codes (select up to 6)
Codes downloaded from Emonitor

Rectangular
Hanning
Hamming
Flat Top

Enpac 2500 Technical Specifications