4 intermediate circuit, 6wiring, 6 power element – Pilz PMCprimo DriveP.01/AA0/4/0/0/208-480VAC User Manual
Page 123
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
6-19
6.6
Power element
6
Wiring
Use the following fuses for F
B1
and F
B2
, depending on the device type.
US types in brackets
6.6.4
Intermediate circuit
Intermediate circuit
6-
][Verdr_Leiterquerschnitte_Verweis
Under “Connection cables”, please note the requirements for the:
`
Cable cross sections
`
Insulation material
][Verdr_Zwischenkreis_protego_D
The connections for the intermediate circuit are
`
not short circuit and earth fault proof
`
Not reverse polarity protected.
][Funktion_Zwischenkreis_Wichtig
Fuse
Device type
01, 03
06
12
24
Blow-out fuse or similar
6 AT
(FRS-6)
10 AT
(FRS-10)
16 AT
(FRS-16)
25 AT
(FRS-25)
Connector pin assignment
Connector X8
Pin
Designation
Description
1
-DC
Intermediate circuit voltage -DC
2
+Rbe/+DC
Intermediate circuit voltage +DC
Connection
Output/input circuit
Intermediate circuit
Cable runs
≤
200 mm:
Use unshielded single wires
(2.5 mm²)
Cable runs > 200 mm:
Use shielded cables.
X8
-DC 1
+RBe 2
+RBi 3
-RB 4
1
RBe/+DC
2
PMCprotego
X8
-DC
PMCprotego
X8
1
2
PMCprotego
RBe/+DC
-DC