6.7

Control element

6

Wiring

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

6-22

6.7.2

Digital inputs

Digital inputs

6-

][Verdr_Leiterquerschnitte_Verweis

Under “Connection cables”, please note the requirements for the:

`

Cable cross sections

`

Insulation material

][Verdr_DI_protego_D

Connector pin assignment

Connector X3A/X3B

Pin

Designation

Description

1

ENABLE

Enable input

2

DIGITAL-IN1

Digital input 1

3

DIGITAL-IN2

Digital input 2

4

DIGITAL-IN3

Digital input 3

5

DIGITAL-IN4

Digital input 4

6

DIGITAL-INOUT 1

Digital input or output 1

7

DIGITAL-INOUT 2

Digital input or output 2

16

DGND

Reference earth for digital inputs and outputs

Connector X4A/X4B

Pin

Designation

Description

3

STO2-ENABLE

STO – Safe torque off, 2nd shutdown route

2, 5

XGND

Reference earth for 24 VDC

6

STO1-ENABLE

STO – Safe torque off, 1st shutdown route

Connection

Input circuit

Digital input

24 VDC

Referenced to earth: Always connect
DGND (X3B/16) to I/O-GND on the
control system

PSTOP, NSTOP: Evaluation of limit
switch

Pin 6 and 7 is configured as a digital
input in the commissioning software

X3A

1

2

3

4

X3B

5

6

7

8

9

10

12

13

14

15

16

11

X4A

1

2

X4B

4

5

3

6

NSTOP

1

ENABLE

DIGITAL-IN1

2

3

4

DGND

5

PMCprotego

24 V

I/O-GND

X3A

DIGITAL-INOUT1

DIGITAL-IN4

DIGITAL-IN3

DIGITAL-IN2

DIGITAL-INOUT2

6

7

X3B

16

ENABLE

PSTOP

Advertising
This manual is related to the following products:

PMCprimo DriveP.01/AA0/5/0/0/208-480VAC, PMCprimo DriveP.12/AA0/4/0/0/208-480VAC, PMCprimo DriveP.12/AA0/4/P/0/208-480VAC, PMCprimo DriveP.03/AA0/4/0/0/208-480VAC, PMCprimo DriveP.06/AA0/4/0/0/208-480VAC, PMCprimo DriveP.24/ABB/4/0/0/208-480VAC, PMCprimo DriveP.03/AB0/5/0/0/208-480VAC, PMCprimo DriveP.06/AB0/2/0/0/208-480VAC, PMCprimo DriveP.03/AB0/3/0/0/208-480VAC, PMCprimo DriveP.06/AB0/3/0/0/208-480VAC, PMCprimo DriveP.12/AB0/2/0/0/208-480VAC, PMCprimo DriveP.12/ABC/4/P/0/208-480VAC, PMCprimo DriveP.12/AB0/3/0/0/208-480VAC, PMCprimo DriveP.03/AB0/2/0/0/208-480VAC, PMCprimo DriveP.12/AAC/4/0/0/208-480VAC, PMCprimo DriveP.24/AA0/5/0/0/208-480VAC, PMCprimo DriveP.12/AA0/2/0/0/208-480VAC, PMCprotego D.01/000/0/0/2/208-480VAC, PMCprotego D.03/000/0/0/2/208-480VAC, PMCprotego D.06/000/0/0/2/208-480VAC, PMCprotego D.12/000/0/0/2/208-480VAC, PMCprotego D.24/000/0/0/2/208-480VAC, PMCprotego D.12/000/0/P/2/208-480VAC, PMCprotego D.24/000/0/P/2/208-480VAC, PMCprotego D.01/200/0/0/2/208-480VAC, PMCprotego D.01/100/0/0/2/208-480VAC, PMCprotego D.01/010/0/0/2/208-480VAC, PMCprotego D.06/010/0/0/2/208-480VAC, PMCprotego D.06/100/0/0/2/208-480VAC, PMCprotego D.06/200/0/0/2/208-480VAC, PMCprotego D.03/010/0/0/2/208-480VAC, PMCprotego D.03/200/0/0/2/208-480VAC, PMCprotego D.03/100/0/0/2/208-480VAC, PMCprotego D.12/010/0/0/2/208-480VAC, PMCprotego D.24/200/0/P/2/208-480VAC, PMCprotego D.12/200/0/0/2/208-480VAC, PMCprotego D.12/100/0/0/2/208-480VAC, PMCprotego D.12/010/0/P/2/208-480VAC, PMCprotego D.12/200/0/P/2/208-480VAC, PMCprotego D.24/100/0/P/2/208-480VAC, PMCprotego D.24/010/0/P/2/208-480VAC, PMCprotego D.12/100/0/P/2/208-480VAC, PMCprotego D.24/200/0/0/2/208-480VAC, PMCprotego D.24/100/0/0/2/208-480VAC, PMCprotego D.24/010/0/0/2/208-480VAC