4 safety function sto with safety card, 5 reaction time, 6 connection example for sto, single-channel – Pilz PMCprimo DriveP.01/AA0/4/0/0/208-480VAC User Manual

Page 52: 4function description, 3 control element

Advertising
background image

4.3

Control element

4

Function Description

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

4-20

4.3.3.4

Safety function STO with safety card

Safety function STO with safety card

4-

][Funktion_STO_mit_Sicherheitskarte

With a safety card inserted, activation of the safety function STO can be

single or dual-channel.

4.3.3.5

Reaction time

Reaction time

4-

][Funktion_STO_Reaktionszeit

The reaction time of the safety function STO, from the falling edge at the

inputs STO1-ENABLE and STO2-ENABLE to the removal of power to

the motor, is

`

2 ms on the shutdown route STO1

`

1 ms on the shutdown route STO2

4.3.3.6

Connection example for STO, single-channel

Connection example for STO, single-channel

4-

][Funktion_STO_Beispiel_einkanalig

The following circuit example illustrates single-channel activation of the

safety function STO.

`

The drives are switched via a safety gate.

`

Safety gates S1/S2 are monitored by a safety relay PNOZ s3.

STO single-channel with safety card
PMCprotego S2 (or when the 2nd shutdown
route is not used on the safety card
PMCprotego S1)

Safety function is activated internally via the
safety card's STO function.

The input STO1-ENABLE has no function.

The input STO2-ENABLE must be connected to
24 VDC.

STO dual-channel with safety card
PMCprotego S1

Safety function is activated internally via the
safety card's STO function
and
output STO SIL3 on the safety card is connect-
ed to STO2-ENABLE as a 2nd shutdown route.

The input STO1-ENABLE has no function.

X4

STO1-ENABLE

STO2-ENABLE

6

3

PMCprotego D.x

PMCpr

otego S2

24 V

POWER

3

STO

X4

STO1-ENABLE

STO2-ENABLE

6

3

PMCprotego D.x

PMCpr

otego S1

X30

19

STO SIL3

STO

STO

POWER

3

Advertising
This manual is related to the following products:

PMCprimo DriveP.01/AA0/5/0/0/208-480VAC, PMCprimo DriveP.12/AA0/4/0/0/208-480VAC, PMCprimo DriveP.12/AA0/4/P/0/208-480VAC, PMCprimo DriveP.03/AA0/4/0/0/208-480VAC, PMCprimo DriveP.06/AA0/4/0/0/208-480VAC, PMCprimo DriveP.24/ABB/4/0/0/208-480VAC, PMCprimo DriveP.03/AB0/5/0/0/208-480VAC, PMCprimo DriveP.06/AB0/2/0/0/208-480VAC, PMCprimo DriveP.03/AB0/3/0/0/208-480VAC, PMCprimo DriveP.06/AB0/3/0/0/208-480VAC, PMCprimo DriveP.12/AB0/2/0/0/208-480VAC, PMCprimo DriveP.12/ABC/4/P/0/208-480VAC, PMCprimo DriveP.12/AB0/3/0/0/208-480VAC, PMCprimo DriveP.03/AB0/2/0/0/208-480VAC, PMCprimo DriveP.12/AAC/4/0/0/208-480VAC, PMCprimo DriveP.24/AA0/5/0/0/208-480VAC, PMCprimo DriveP.12/AA0/2/0/0/208-480VAC, PMCprotego D.01/000/0/0/2/208-480VAC, PMCprotego D.03/000/0/0/2/208-480VAC, PMCprotego D.06/000/0/0/2/208-480VAC, PMCprotego D.12/000/0/0/2/208-480VAC, PMCprotego D.24/000/0/0/2/208-480VAC, PMCprotego D.12/000/0/P/2/208-480VAC, PMCprotego D.24/000/0/P/2/208-480VAC, PMCprotego D.01/200/0/0/2/208-480VAC, PMCprotego D.01/100/0/0/2/208-480VAC, PMCprotego D.01/010/0/0/2/208-480VAC, PMCprotego D.06/010/0/0/2/208-480VAC, PMCprotego D.06/100/0/0/2/208-480VAC, PMCprotego D.06/200/0/0/2/208-480VAC, PMCprotego D.03/010/0/0/2/208-480VAC, PMCprotego D.03/200/0/0/2/208-480VAC, PMCprotego D.03/100/0/0/2/208-480VAC, PMCprotego D.12/010/0/0/2/208-480VAC, PMCprotego D.24/200/0/P/2/208-480VAC, PMCprotego D.12/200/0/0/2/208-480VAC, PMCprotego D.12/100/0/0/2/208-480VAC, PMCprotego D.12/010/0/P/2/208-480VAC, PMCprotego D.12/200/0/P/2/208-480VAC, PMCprotego D.24/100/0/P/2/208-480VAC, PMCprotego D.24/010/0/P/2/208-480VAC, PMCprotego D.12/100/0/P/2/208-480VAC, PMCprotego D.24/200/0/0/2/208-480VAC, PMCprotego D.24/100/0/0/2/208-480VAC, PMCprotego D.24/010/0/0/2/208-480VAC