6 expansion card with devicenet interface, 4function description, 4 expansion cards – Pilz PMCprimo DriveP.01/AA0/4/0/0/208-480VAC User Manual

Page 82

Advertising
background image

4.4

Expansion cards

4

Function Description

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

4-50

4.4.6

Expansion card with DeviceNet interface

Expansion card with DeviceNet interface

4-

][Funktion_Erw_DeviceNet_protego_D

The DeviceNet expansion card is available as an accessory.

Fig. 4-16:

Front view of DeviceNet expansion card

LEDs

The “Net status” LED shows the status of both the expansion card and

the network.

Setting the station address

Valid values for the station address are 0 … 63

D

.

`

Use the two rotary switches under “Address” to set the station ad-

dress.

There are three ways in which you can set the servo amplifier's station

address:

LED

Description

Off

The device is offline.
- The device has not yet completed the Dup_MAC_ID test.
- The device may not be switched on.

Green

The device is online and is running normally. The connec-
tions are established. The device is assigned to a master.

Flashes green

The device is online and is running normally. The connec-
tions are not established.
- The device has passed the Dup_MAC_ID test and is online,
but the connections to other nodes are not yet established.
- This device has not been assigned to a master.
- Configuration is missing, incomplete or invalid

Flashes red

Recoverable error and/or at least one I/O connection is in
wait status.

Red

- An unrecoverable error has occurred on the device. It may
need to be exchanged.
- Communication device has failed. The device has detected
an error that's preventing communication with the network
(e.g. duplicated MAC ID or BUSOFF).

Advertising
This manual is related to the following products:

PMCprimo DriveP.01/AA0/5/0/0/208-480VAC, PMCprimo DriveP.12/AA0/4/0/0/208-480VAC, PMCprimo DriveP.12/AA0/4/P/0/208-480VAC, PMCprimo DriveP.03/AA0/4/0/0/208-480VAC, PMCprimo DriveP.06/AA0/4/0/0/208-480VAC, PMCprimo DriveP.24/ABB/4/0/0/208-480VAC, PMCprimo DriveP.03/AB0/5/0/0/208-480VAC, PMCprimo DriveP.06/AB0/2/0/0/208-480VAC, PMCprimo DriveP.03/AB0/3/0/0/208-480VAC, PMCprimo DriveP.06/AB0/3/0/0/208-480VAC, PMCprimo DriveP.12/AB0/2/0/0/208-480VAC, PMCprimo DriveP.12/ABC/4/P/0/208-480VAC, PMCprimo DriveP.12/AB0/3/0/0/208-480VAC, PMCprimo DriveP.03/AB0/2/0/0/208-480VAC, PMCprimo DriveP.12/AAC/4/0/0/208-480VAC, PMCprimo DriveP.24/AA0/5/0/0/208-480VAC, PMCprimo DriveP.12/AA0/2/0/0/208-480VAC, PMCprotego D.01/000/0/0/2/208-480VAC, PMCprotego D.03/000/0/0/2/208-480VAC, PMCprotego D.06/000/0/0/2/208-480VAC, PMCprotego D.12/000/0/0/2/208-480VAC, PMCprotego D.24/000/0/0/2/208-480VAC, PMCprotego D.12/000/0/P/2/208-480VAC, PMCprotego D.24/000/0/P/2/208-480VAC, PMCprotego D.01/200/0/0/2/208-480VAC, PMCprotego D.01/100/0/0/2/208-480VAC, PMCprotego D.01/010/0/0/2/208-480VAC, PMCprotego D.06/010/0/0/2/208-480VAC, PMCprotego D.06/100/0/0/2/208-480VAC, PMCprotego D.06/200/0/0/2/208-480VAC, PMCprotego D.03/010/0/0/2/208-480VAC, PMCprotego D.03/200/0/0/2/208-480VAC, PMCprotego D.03/100/0/0/2/208-480VAC, PMCprotego D.12/010/0/0/2/208-480VAC, PMCprotego D.24/200/0/P/2/208-480VAC, PMCprotego D.12/200/0/0/2/208-480VAC, PMCprotego D.12/100/0/0/2/208-480VAC, PMCprotego D.12/010/0/P/2/208-480VAC, PMCprotego D.12/200/0/P/2/208-480VAC, PMCprotego D.24/100/0/P/2/208-480VAC, PMCprotego D.24/010/0/P/2/208-480VAC, PMCprotego D.12/100/0/P/2/208-480VAC, PMCprotego D.24/200/0/0/2/208-480VAC, PMCprotego D.24/100/0/0/2/208-480VAC, PMCprotego D.24/010/0/0/2/208-480VAC