4.4

Expansion cards

4

Function Description

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

4-44

4.4.3.2

Encoder emulation

Encoder emulation

4-

][Funktion_Encoder_Emu

The PosI/O-Monitor expansion card is required for encoder emulation.

Output signals for a higher level position controller are generated from

signals from the resolver or a SinCos encoder. The position of the motor

shaft is calculated in the servo amplifier from the cyclical-absolute sig-

nals from the resolver or SinCos encoder:

`

Signals are incremental encoder compatible

`

Signals for the SSI interface

][Funktion_Encoder_Emu_ROD

Output of incremental encoder signals

Functions:

With this encoder emulation, a total of six tracks are generated from the

existing output signals from the resolver or SinCos encoder; a higher

level control system uses these tracks for positioning. These six tracks

are track A, B and NI (zero pulse) and their inverted signals A\, B\ and

NI\.

Parameter setting:

The following can be set in the “Encoder Emulation” window in the com-

missioning software:

`

Position of the zero pulse within one mechanical revolution (NI-OFF-

SET parameter)

`

Resolution (before multiplication) in counts/revolution

`

ENCMODE = 1: Incremental encoder compatible signals from the re-

solver or SinCos encoder

`

ENCMODE = 3: Encoder signal from X1 is available at X5

Parameter
ENCMODE

Encoder type

Resolution

Zero pulse

1 = incremental encoder

Resolver

256 … 4096 (2

8

... 2

12

)

One per revolution (only
when A = B = 1)

SinCos encoder

256 … 524288 (2

8

… 2

19

)

One per revolution (only
when A = B = 1)

3 = Incremental encoder in-
terpolation

SinCos encoder

4 ... 256 (2

2

... 2

7

)

TTL counts * resolution of
encoder

Encoder signal passed from
X1 to X5

Advertising
This manual is related to the following products:

PMCprimo DriveP.01/AA0/5/0/0/208-480VAC, PMCprimo DriveP.12/AA0/4/0/0/208-480VAC, PMCprimo DriveP.12/AA0/4/P/0/208-480VAC, PMCprimo DriveP.03/AA0/4/0/0/208-480VAC, PMCprimo DriveP.06/AA0/4/0/0/208-480VAC, PMCprimo DriveP.24/ABB/4/0/0/208-480VAC, PMCprimo DriveP.03/AB0/5/0/0/208-480VAC, PMCprimo DriveP.06/AB0/2/0/0/208-480VAC, PMCprimo DriveP.03/AB0/3/0/0/208-480VAC, PMCprimo DriveP.06/AB0/3/0/0/208-480VAC, PMCprimo DriveP.12/AB0/2/0/0/208-480VAC, PMCprimo DriveP.12/ABC/4/P/0/208-480VAC, PMCprimo DriveP.12/AB0/3/0/0/208-480VAC, PMCprimo DriveP.03/AB0/2/0/0/208-480VAC, PMCprimo DriveP.12/AAC/4/0/0/208-480VAC, PMCprimo DriveP.24/AA0/5/0/0/208-480VAC, PMCprimo DriveP.12/AA0/2/0/0/208-480VAC, PMCprotego D.01/000/0/0/2/208-480VAC, PMCprotego D.03/000/0/0/2/208-480VAC, PMCprotego D.06/000/0/0/2/208-480VAC, PMCprotego D.12/000/0/0/2/208-480VAC, PMCprotego D.24/000/0/0/2/208-480VAC, PMCprotego D.12/000/0/P/2/208-480VAC, PMCprotego D.24/000/0/P/2/208-480VAC, PMCprotego D.01/200/0/0/2/208-480VAC, PMCprotego D.01/100/0/0/2/208-480VAC, PMCprotego D.01/010/0/0/2/208-480VAC, PMCprotego D.06/010/0/0/2/208-480VAC, PMCprotego D.06/100/0/0/2/208-480VAC, PMCprotego D.06/200/0/0/2/208-480VAC, PMCprotego D.03/010/0/0/2/208-480VAC, PMCprotego D.03/200/0/0/2/208-480VAC, PMCprotego D.03/100/0/0/2/208-480VAC, PMCprotego D.12/010/0/0/2/208-480VAC, PMCprotego D.24/200/0/P/2/208-480VAC, PMCprotego D.12/200/0/0/2/208-480VAC, PMCprotego D.12/100/0/0/2/208-480VAC, PMCprotego D.12/010/0/P/2/208-480VAC, PMCprotego D.12/200/0/P/2/208-480VAC, PMCprotego D.24/100/0/P/2/208-480VAC, PMCprotego D.24/010/0/P/2/208-480VAC, PMCprotego D.12/100/0/P/2/208-480VAC, PMCprotego D.24/200/0/0/2/208-480VAC, PMCprotego D.24/100/0/0/2/208-480VAC, PMCprotego D.24/010/0/0/2/208-480VAC