Power element, 1 mains voltage, 4function description – Pilz PMCprimo DriveP.01/AA0/4/0/0/208-480VAC User Manual
Page 35: 2 power element
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
4-3
4.2
Power element
4
Function Description
4.2
Power element
4200
Power element
4-
][Funktion_Leistungsteil
The power element of the servo amplifier converts the fixed voltage and
frequency of the mains into a variable voltage and frequency for driving
the motor This means that the rotational speed and torque are infinitely
variable. The power element consists of:
`
Filter A
`
Rectifier B
`
Charging circuit with intermediate circuit C
`
Brake chopper D
`
Inverted rectifier E
Fig. 4-2:
Power element
4.2.1
Mains voltage
Mains voltage
4-
][Funktion_Netzspannung_protego_D
The servo amplifier is suitable for connection to TT and TN networks.
The voltage range of the servo amplifier is 3 x 208 VAC - 3 x 480 VAC.
Please note the maximum permitted voltages between the external con-
ductors (L1, L2, L3) and the servo amplifier housing:
`
Periodic overvoltages between the external conductors and the hous-
ing: Max. 1000 V (amplitude)
`
Voltage spikes (< 50
μ
s) between the external conductors in accord-
ance with EN 61800: Max. 1000 V
`
Voltage spikes (< 50
μ
s) between the external conductors and the
housing: Max. 2000 V
Direct connection to PMCprotego D
`
208 – 240 V mains supplies without earthed star point (asymmetrically
earthed or unearthed mains supplies), see Fig. (2) – (6)
`
208 – 480 V mains supplies with earthed star point, see Figure (1)
Connection via isolating transformer
`
400 – 480 V mains supplies without earthed star point (asymmetrically
earthed or unearthed mains supplies), see Fig. (7) – (11)
A
C
E
3
B
D