Power element, 1 mains voltage, 4function description – Pilz PMCprimo DriveP.01/AA0/4/0/0/208-480VAC User Manual

Page 35: 2 power element

Advertising
background image

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

4-3

4.2

Power element

4

Function Description

4.2

Power element

4200

Power element

4-

][Funktion_Leistungsteil

The power element of the servo amplifier converts the fixed voltage and

frequency of the mains into a variable voltage and frequency for driving

the motor This means that the rotational speed and torque are infinitely

variable. The power element consists of:

`

Filter A

`

Rectifier B

`

Charging circuit with intermediate circuit C

`

Brake chopper D

`

Inverted rectifier E

Fig. 4-2:

Power element

4.2.1

Mains voltage

Mains voltage

4-

][Funktion_Netzspannung_protego_D

The servo amplifier is suitable for connection to TT and TN networks.

The voltage range of the servo amplifier is 3 x 208 VAC - 3 x 480 VAC.

Please note the maximum permitted voltages between the external con-

ductors (L1, L2, L3) and the servo amplifier housing:

`

Periodic overvoltages between the external conductors and the hous-

ing: Max. 1000 V (amplitude)

`

Voltage spikes (< 50

μ

s) between the external conductors in accord-

ance with EN 61800: Max. 1000 V

`

Voltage spikes (< 50

μ

s) between the external conductors and the

housing: Max. 2000 V

Direct connection to PMCprotego D

`

208 – 240 V mains supplies without earthed star point (asymmetrically

earthed or unearthed mains supplies), see Fig. (2) – (6)

`

208 – 480 V mains supplies with earthed star point, see Figure (1)

Connection via isolating transformer

`

400 – 480 V mains supplies without earthed star point (asymmetrically

earthed or unearthed mains supplies), see Fig. (7) – (11)

A

C

E

3

B

D

Advertising
This manual is related to the following products:

PMCprimo DriveP.01/AA0/5/0/0/208-480VAC, PMCprimo DriveP.12/AA0/4/0/0/208-480VAC, PMCprimo DriveP.12/AA0/4/P/0/208-480VAC, PMCprimo DriveP.03/AA0/4/0/0/208-480VAC, PMCprimo DriveP.06/AA0/4/0/0/208-480VAC, PMCprimo DriveP.24/ABB/4/0/0/208-480VAC, PMCprimo DriveP.03/AB0/5/0/0/208-480VAC, PMCprimo DriveP.06/AB0/2/0/0/208-480VAC, PMCprimo DriveP.03/AB0/3/0/0/208-480VAC, PMCprimo DriveP.06/AB0/3/0/0/208-480VAC, PMCprimo DriveP.12/AB0/2/0/0/208-480VAC, PMCprimo DriveP.12/ABC/4/P/0/208-480VAC, PMCprimo DriveP.12/AB0/3/0/0/208-480VAC, PMCprimo DriveP.03/AB0/2/0/0/208-480VAC, PMCprimo DriveP.12/AAC/4/0/0/208-480VAC, PMCprimo DriveP.24/AA0/5/0/0/208-480VAC, PMCprimo DriveP.12/AA0/2/0/0/208-480VAC, PMCprotego D.01/000/0/0/2/208-480VAC, PMCprotego D.03/000/0/0/2/208-480VAC, PMCprotego D.06/000/0/0/2/208-480VAC, PMCprotego D.12/000/0/0/2/208-480VAC, PMCprotego D.24/000/0/0/2/208-480VAC, PMCprotego D.12/000/0/P/2/208-480VAC, PMCprotego D.24/000/0/P/2/208-480VAC, PMCprotego D.01/200/0/0/2/208-480VAC, PMCprotego D.01/100/0/0/2/208-480VAC, PMCprotego D.01/010/0/0/2/208-480VAC, PMCprotego D.06/010/0/0/2/208-480VAC, PMCprotego D.06/100/0/0/2/208-480VAC, PMCprotego D.06/200/0/0/2/208-480VAC, PMCprotego D.03/010/0/0/2/208-480VAC, PMCprotego D.03/200/0/0/2/208-480VAC, PMCprotego D.03/100/0/0/2/208-480VAC, PMCprotego D.12/010/0/0/2/208-480VAC, PMCprotego D.24/200/0/P/2/208-480VAC, PMCprotego D.12/200/0/0/2/208-480VAC, PMCprotego D.12/100/0/0/2/208-480VAC, PMCprotego D.12/010/0/P/2/208-480VAC, PMCprotego D.12/200/0/P/2/208-480VAC, PMCprotego D.24/100/0/P/2/208-480VAC, PMCprotego D.24/010/0/P/2/208-480VAC, PMCprotego D.12/100/0/P/2/208-480VAC, PMCprotego D.24/200/0/0/2/208-480VAC, PMCprotego D.24/100/0/0/2/208-480VAC, PMCprotego D.24/010/0/0/2/208-480VAC