4 analogue inputs, 6wiring, 7 control element – Pilz PMCprimo DriveP.01/AA0/4/0/0/208-480VAC User Manual
Page 130
6.7
Control element
6
Wiring
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
6-26
6.7.4
Analogue inputs
Analogue inputs
6-
][Verdr_Leiterquerschnitte_Verweis
Under “Connection cables”, please note the requirements for the:
`
Cable cross sections
`
Insulation material
][Verdr_AI_protego_D
Connector pin assignment
Connector X3A/X3B
Pin
Designation
Description
9
ANALOG-IN1-
Analogue input 1-
10
ANALOG-IN1-
Analogue input 1+
11
ANALOG-IN2-
Analogue input 2-
12
ANALOG-IN2+
Analogue input 2+
13
AGND
Reference earth for analogue inputs
Connection
Input circuit
Analogue input
- Signal range –10 ... +10 V
- Referenced to earth: Always con-
nect AGND (X3B/13) to CNC-GND
on the control system
- Twisted pair, shielded
- Shield connection on the front plate
X3A
1
2
3
4
X3B
5
6
7
8
9
10
12
13
14
15
16
11
+O1
9
ANALOG-IN1-
10
11
12
AGND
13
PMCprotego
-O1
+/- 10 V
+O2
-O2
+/- 10 V
CNC-GND
GND
X3B
Shield
ANALOG-IN1+
ANALOG-IN2-
ANALOG-IN2+