Series 9130 Operations Manual Rev -

113

Sample Event Assignments


Events can be assigned to cycle any relay on and off. In the example below, Event 6 could cause a buzzer to
go off or a light to turn on, signaling the end of a cycle. However, this is strictly an example. Events are
customizable per the system.

The following list is an example of how the operator could setup under System Management in Configurator
some of the vacuum event assignments.

Event 0

Spare

Event 1

Cycle Running/Start Pump Down

Event 2

Spare

Event 3

Vacuum Cool

Event 4

Partial Pressure

Event 5

Gas Fan Cool

Event 6

End of Cycle

Event 7

Spare

Event 8

Spare

Event 9

Spare

Event 10

Static Cool

Flash Card Management

This section will show the user how to pull logged data from the operator interface using TS Manager.

From the TS Manager home screen, select Tools  Communications  Advanced Download &
Maintenance










The Transfer Data tab is used to download data from the selected touch screen. The specified recorder is
identified on the drop down list from the main TS Manager Screen.
There are 2 ways to synchronize data. This can be done using the Screen as the source of the data (network
connection) or Disk source (flash card from the screen).

Note: Users can also download data from the

main TS Manager screen using
the “Download Data” button on
the top right corner

.