Thermocouple Check

Source 1 – Source
These are the values for the first, second, and third
source. The options are: not used, Instrument 1 –
Instrument 27, n/a, or Input 3 – Input 1.

Tolerance Band
This is the tolerance band for the thermocouple.
The range is –9999 to 9999.

Source 2 Offset
This is the offset for source 2. The range is –9999 to
9999.


Source 3 Offset
This is the offset for source 3. The range is –9999 to 9999.


Relay Assignments

The 9130 controller has the option of using eight
relay outputs. All of the relays have a positive
common terminal and independent negative
terminals. All of the relays are configured in a
normally closed position except relay number
eight, which has both a normally closed (NC) and
a normally open (NO) terminal. These relays can
be configured to work with events, alarms, loops,
burnoff and alarm combinations.

Relay Output Terminals
Relay Output 1 – terminals 7 and 8
Relay Output 2 – terminals 7 and 9
Relay Output 3 – terminals 7 and 10
Relay Output 4 – terminals 7 and 11
Relay Output 5 – terminals 7 and 12
Relay Output 6 – terminals 7 and 13
Relay Output 7 – terminals 7 and 14
Relay Output 8 – terminals 7 and 15 NC
Relay Output 8 – terminals 7 and 16 NO

Relay Output Choices
Loop 1 fwd

Event 6

Loop 1 rev

Event 7

N/A

Event 8

N/A

Event 9

N/A

Event 10

N/A

Event 11

Programmer Alarm

Event 12

Alarm 1

Event 13

Alarm 2

Event 14

Alarm 3

Event 15

Event 0

TC Redundancy Select (OFF = TC 1; ON = TC 2)