Series 9130 Operations Manual Rev -

41

Alarm Polarity

This option will allow the user to set up the polarity of the
alarms, or determine whether the Normally Closed option
or the Normally Open option makes the alarm active.
The alarms to configure are: Programmer Alarm, Alarm 1,
Alarm 2, and Alarm 3. The options for each alarm are:
Normally Open or Normally Closed.

The Return button will return the user to the menu screen.


Event Hold/Reset

The Event Hold/Reset menu option provides the user manual
control of actual event outputs. This is useful when testing
wiring and field devices.

Hold Instrument Number
Clicking on this value will display an input box from which the
user can select a new value. The range is 0 to 25.

Hold Minimum PV
Clicking on this value will display an input box from which the
user can select a new value. The range is -32768 to 32767.

Hold Maximum PV
Clicking on this value will display an input box from which the user can select a new value. The range is -
32768 to 32767.

Event for Program Run
Clicking on this value will display an input box from which the user can select a new value. The range is –1
(Disable) to 15.

Event for Program Reset
Clicking on this value will display an input box from which the user can select a new value. The range is –1
(Disable) to 15.

Program Number to Run
This is the recipe number to run. The range is: 0 – 300.

Event 0 Through Event 15
The input box for these events has two drop-down lists. The top list contains active and inactive, and the
bottom list contains closed and open.

The Return button will return the user to the menu screen.