Zone assignments – Super Systems 9130 Series User Manual

Page 33

Advertising
background image

Series 9130 Operations Manual Rev -

32

Zone Assignments


WARNING: This screen should not be changed
without consulting SSi at 800-666-4330.

*Only used when running recipes

*Slave Instrument Setup must be configured
prior to Zone Assignment setup

* Temperature zones link instruments to
Temperature Setpoints

The zone assignment feature allows the
SERIES 9130 program to change set points on
all instruments of a multi-zone furnace. The
SERIES 9130 has up to ten (10) temperature zone assignments available (Zone Assignment 1 – Zone
Assignment 10). The SERIES 9130 programmer looks for appropriate zone assignments whenever a set
point is to be sent to the temperature controller. The temperature set point is sent to every instrument
number in the temperature zone assignment.

If the

ZONE_OFF

(Zone Offset) opcode had been used in the program, the set point sent to the specified

zone instrument would have the offset added. For example, a 3-zone pit furnace, where the bottom zone
usually has a higher set point. The middle zone and the top zone usually have a lower set point. The bottom
zone temperature controller is assigned to zone 1, the middle temperature controllers to zone 2, and the
top zone controller to zone 3.

If the first three steps of a program are as shown below, then the bottom zone set point is 1775, the middle
zone is 1750, and the top zone is 1800.

Step

opcode

Temperature

Option

1

ZONE_OFF

25

Zone 1

2

ZONE_OFF

50

Zone 3

3

SETPT

1750


The first step sets the offset for zone 1 to 25 degrees; therefore, the bottom zone controller would be sent a
set point of 1775 when step 3 is executed. Likewise step 2 sets the offset for zone 3 to 50 degrees. The top
zone then receives a set point of 1800. The middle zone controller would receive the 1750. The temperature
controller displayed on the Status Display is instrument #2. If instrument #2 were the top zone controller
then the Status Display would show the 1800-degree set point.

When using the multi-zone offset feature, the temperature controller assigned as instruments 1 and 2
should be in zones that will not be offset.

Temp Instrument
This will allow the user to set the temperature instrument for the zone assignment. The options are:
Loop 1 (N/A)

Instrument 5

Instrument 12

Instrument 19

Temperature Loop

Instrument 6

Instrument 13

Instrument 20

Loop 3 (N/A)

Instrument 7

Instrument 14

Instrument 21

Instrument 1

Instrument 8

Instrument 15

Instrument 22

Instrument 2

Instrument 9

Instrument 16

Instrument 23

Instrument 3

Instrument 10

Instrument 17

Instrument 24

Instrument 4

Instrument 11

Instrument 18

Instrument 25