RS-232 Connections

Chapter 5 - Features and Applications

Page 127

RS-232 Connections

Refer to the “Hardware Reference” chapter for the ION 7500 and ION 7600 meters’
RS-232 specifications.

An RS-232 connection is made at the male DB9 connector (COM1) at the back of
the meter. The meter acts as a DTE device in all RS-232 connections. Use a null
modem cable for connecting a meter to a workstation or use a standard straight-
through RS-232 cable for connecting to an external modem. In either case, one end
of the cable must be equipped with DB9 female connector for mating with the DB9
male connector on the meter. The maximum cable length is 50 feet (15.2 m).

Computer Connections

Meter Connections

External Modem Connections

RS-232

50 feet (15.2

m) max

Null modem

DB9 female

connector to

COM1

RS-232

RS-485 loop

50 feet (15.2

m) max

RS-232 to RS-485

Converter

DB9 female

connector to

COM1

50 feet (15.2

m) max

RS-232

DB9 female

connector to

COM1

Telephone network connection

between workstation modem

and remote modem

Remote modem

Advertising